  • What should I do if the high and low temperature test chamber has problems? What should I do if the high and low temperature test chamber has problems?
    Jun 23, 2025
    High and low temperature test chamber may encounter a variety of problems in the process of use, the following is a summary of potential faults and their causes from different perspectives: 1. Core system failure Temperature out of control Reason: PID control parameters are out of balance, ambient temperature exceeds the design range of the equipment, multi-zone temperature interference. Case: In a special environment workshop, the external high temperature causes the refrigeration system to overload, resulting in temperature drift. Humidity is abnormal Reason: poor water quality of humidification leads to scaling and nozzle blockage, failure of ultrasonic humidifier piezoelectric sheet, and incomplete regeneration of dehumidification desiccant. Special phenomenon: reverse condensation occurs during high humidity test, resulting in the actual humidity in the box being lower than the set value. 2. Mechanical and structural problems Air flow is disorganized Performance: There is a temperature gradient of more than 3℃ in the sample area. Root cause: the customized sample rack changed the original design air duct and the accumulation of dirt on the centrifugal fan blade led to the destruction of dynamic balance.  sealing failure New failure: the magnetic force of electromagnetic sealing door decreases at low temperature, and the silicone sealing strip becomes brittle and cracks after-70℃. 3. Electrical and control system Intelligent control failure Software level: After firmware upgrade, the temperature dead zone setting error occurs and the historical data overflow causes the program to crash. Hardware level: SSR solid state relay breakdown causes continuous heating and bus communication is subjected to inverter electromagnetic interference. Security protection vulnerabilities Hidden dangers: the synchronous failure of the triple temperature protection relay and the false alarm caused by the expiration of the refrigerant detector calibration. 4. Challenges of special working conditions Specific temperature shock Problem: -40℃ to +150℃ rapid conversion of the evaporator weld stress cracking, thermal expansion coefficient difference resulting in the failure of the observation window seal. Long-term operation attenuation Performance degradation: after 2000 hours of continuous operation, the compressor valve plate wear leads to a decrease of 15% in refrigeration capacity and drift of ceramic heating tube resistance value. 5. Environmental and maintenance impact Infrastructure adaptation Case: The power oscillation of PTC heater caused by the fluctuation of power supply voltage and the water hammer effect of cooling water system damaged the plate heat exchanger. Preventive maintenance blind spots Lesson: Ignoring the positive pressure of the box leads to water entering the bearing chamber and biofilm growth and blockage in the condensate discharge pipe. 6. Pain points of emerging technologies New refrigerant application Challenges: system oil compatibility problems after R448A replaces R404A, and high pressure sealing problems of subcritical CO₂ refrigeration systems. IoT integration risks Fault: The remote control protocol is maliciously attacked, resulting in program tampering and cloud storage failure, resulting in the loss of test evidence chain. Strategy recommendations Intelligent diagnosis: configure vibration analyzer to predict the failure of compressor bearing, and use infrared thermal imager to scan the electrical connection points regularly. Reliability design: key components such as evaporator are made of SUS316L stainless steel to improve corrosion resistance, and redundant temperature control modules are added to the control system. Maintenance innovation: implement a dynamic maintenance plan based on operating hours, and establish an annual refrigerant purity testing system。 The solutions to these problems need to be analyzed in combination with the specific model of the equipment, the use environment and the maintenance history. It is recommended to establish a collaborative maintenance mechanism including the OEM of the equipment, third-party testing institutions and user technical teams. For key test items, it is recommended to configure a dual-machine hot standby system to ensure the continuity of testing.  
    อ่านเพิ่มเติม
  • What are the delivery standards of Guangdong Hongzhan? What are the delivery standards of Guangdong Hongzhan?
    Jun 23, 2025
    (1) Equipment installation and commissioning On-site service: technical personnel will deliver the goods free of charge and complete the mechanical assembly, electrical wiring and debugging. The debugging parameters shall meet the temperature and humidity, salt spray deposition amount and other indicators in the customer's technical agreement. Acceptance criteria: provide a third-party measurement report, and unqualified equipment shall be returned or replaced directly. For example, the rain test box shall pass 100% acceptance. (2) Customer training system Operation training: covers equipment start and stop, program setting and daily maintenance, customized for different user scenarios such as quality inspection institutions and automobile enterprises. Deep maintenance training: including fault diagnosis (such as troubleshooting of humidity system in high and low temperature and humidity test chamber) and spare parts replacement to improve customers' independent maintenance ability. (3) Technical support and response Instant response: respond to repair demand within 15 minutes, and solve routine faults within 48 hours (negotiate with remote areas). Remote diagnosis: through video guidance or remote access software, quickly locate the problem (such as abnormal dust concentration in the sand test chamber). (4) Spare parts supply and maintenance Make spare parts plan, give priority to the supply of wear and tear parts from cooperative units (such as China Railway Inspection and Certification Center, China Electronics Technology Group), and reduce downtime. Non-manual damage is free of charge during the warranty period, and paid services are provided after the warranty period with transparent charges.
    อ่านเพิ่มเติม
  • What should be paid attention to in summer when using the ice water impact test chamber? What should be paid attention to in summer when using the ice water impact test chamber?
    Jun 16, 2025
      When the Guangdong Hongzhan ice water impact test chamber is used in summer, the following matters should be paid special attention to to ensure the stable operation of the equipment and the accuracy of the test results: 1. Environment and heat dissipation management   Enhance ventilation and heat dissipation High temperature in summer is easy to lead to the decrease of equipment heat dissipation efficiency. Ensure that at least 10cm space is reserved around the equipment to promote air circulation. If the equipment adopts air cooling system, the condenser surface dust should be cleaned regularly to prevent poor heat dissipation and overheating of the compressor.Control the environmental temperature and humidity. Avoid placing the equipment in the direct sunlight area. It is recommended that the laboratory temperature be kept at 25±5℃ and the humidity be lower than 85%. High temperature and high humidity environment may accelerate the accumulation of frost or condensation water on the equipment, so it is necessary to increase the dehumidification measures. 2. Refrigeration system maintenance   Water quality and tank management Bacteria are easy to breed in summer, so use deionized water or pure water to avoid hard water scaling and blocking pipes. It is recommended to change the tank water every 3 days, and empty and clean the tank before long-term disuse.Refrigeration efficiency monitoring High temperature environment may lead to overload operation of the refrigeration system. The compressor oil condition should be checked regularly to ensure sufficient refrigerant. If the water temperature exceeds the set value (such as 0~4℃), the machine should be stopped immediately for troubleshooting. 3. Frosting and defrosting treatment   Prevent frost aggravation When the humidity is high in summer, the frost rate inside the equipment may accelerate. It is recommended to perform a manual defrosting process after 10 cycles: set the temperature to 30℃ and keep it for 30 minutes, and then drain water to clean the ice crystals on the evaporator surface. Optimize the test interval to avoid continuous long-term low temperature testing. It is recommended to reserve 15 minutes of buffer time between high temperature (e.g., 160℃) and ice water shock cycle to reduce the impact of thermal stress on the equipment. 4. Adjustment of operation specifications   Parameter setting optimization According to the characteristics of the summer environment, the normal temperature recovery stage time can be shortened appropriately (the reference standard is to complete the temperature switch within 20 seconds), but it must ensure that it meets the requirements of GB/T 2423.1 or ISO16750-4 standards.Safety protection should be strengthened. Anti-freezing gloves and goggles should be worn during operation to avoid the adhesion of hands and low-temperature parts caused by sweating. Before opening the door after high temperature test, the temperature inside the box should be confirmed to be below 50℃ to prevent scalding from hot steam. 5. Emergency and long-term shutdown preparation   Fault response If the equipment has E01 (temperature out of tolerance) or E02 (water level abnormal) alarm, you should immediately cut off the power supply and contact the technical support of the manufacturer. Do not disassemble the refrigeration pipeline by yourself.Long-term protection When not used for more than 7 days, the water tank should be emptied, power should be cut off and dust cover should be covered. At the same time, power should be on for 1 hour every half a month to keep the circuit board dry.   Through the above measures, the impact of high temperature and humidity environment in summer on the ice water shock test chamber can be effectively reduced to ensure the reliability of test data and the service life of the equipment. The specific operation details should be adjusted according to the equipment manual and actual working conditions.
    อ่านเพิ่มเติม
  • What are the performance of high and low temperature shock test chamber? What are the performance of high and low temperature shock test chamber?
    Jun 14, 2025
      The high and low-temperature impact test chamber is designed for reliability testing of industrial products under both high and low temperatures. It is used to evaluate the performance of components and materials in industries such as electronics, automotive, aerospace, shipbuilding, and weaponry, as well as in higher education and research institutions, under alternating cycles of high and low temperatures. The main features include: Excellent Conductivity: The alloy cable, made by adding rare earth elements and copper, iron, silicon, and other elements from China, undergoes special processing to achieve a conductivity 62% higher than that of copper. After this process, the cross-sectional area of the alloy conductor is increased by 1.28 to 1.5 times, making the cable's current-carrying capacity and voltage drop comparable to those of copper cables, effectively replacing copper with new alloy materials. Superior Mechanical Properties: Compared to copper cables, the rebound performance of the high and low-temperature impact test chamber is 40% lower, and its flexibility is 25% higher. It also has excellent bending properties, allowing for a much smaller installation radius compared to copper cables, making it easier to install and connect terminals. The special formulation and heat treatment process significantly reduce the creep of the conductor under heat and pressure, ensuring that the electrical connections of the alloy cable are as stable as those of copper cables. Reliable Safety Performance: The high and low-temperature impact test chamber has been rigorously certified by UL in the United States and has been in use for 40 years in countries like the United States, Canada, and Mexico without any issues. Based on advanced American technology, the test chamber has been tested and inspected by multiple domestic institutions, ensuring its reliable safety. Economic Performance Savings: When achieving the same electrical performance, the direct procurement cost of high and low-temperature impact test chambers is 20% to 30% lower than that of copper cables. Since alloy cables are only half the weight of copper cables and have excellent mechanical properties, using alloy cables can reduce transportation and installation costs by more than 20% in general buildings and over 40% in large-span buildings. Using high and low-temperature impact test chambers will have an immeasurable impact on building a resource-efficient society. Excellent Anti-corrosion Performance: When exposed to air at high temperatures, alloy cables immediately form a dense oxide layer that is highly resistant to various forms of corrosion, making them suitable for harsh environments. Additionally, the optimized internal structure of the alloy conductor and the use of silane cross-linked polyethylene insulation material extend the service life of alloy cables by more than 10 years compared to copper cables.                      
    อ่านเพิ่มเติม
  • Maintenance methods for constant temperature and humidity test chambers Maintenance methods for constant temperature and humidity test chambers
    Jun 13, 2025
    1. Dust adhering to the condenser can cause the high-pressure switch of the compressor to trip and issue false alarms. Therefore, dust attached to the cooling grid of the condenser can be removed with a vacuum cleaner every month, or by using a hard-bristled brush after turning on the machine, or by blowing it off with a high-pressure air nozzle.2. The area around the machine and the ground at the bottom should be kept clean at all times to prevent a large amount of dust from being sucked into the unit or reducing equipment performance and causing accidents.3. When opening or closing the door or taking samples from the test chamber, do not touch the sealing strip on the door.4. The core of the constant temperature and humidity test chamber - the refrigeration system should be inspected once a year. Check for leaks in the copper tubes and at each joint and interface. If there are any, inform the manufacturer.5. The humidifier and water tank should be cleaned frequently to avoid scaling and affecting steam emission. Clean them after each test. Timely descaling helps extend the lifespan of the humidification tube and ensures smooth water flow. When cleaning, use a copper brush and then rinse with water.6. The distribution room should be cleaned and inspected more than once a year. Loose nodes can put the entire equipment in a dangerous working state, burn out components, cause fires, alarms, and endanger lives.7. The dry and wet bulb wicks should be checked frequently. Replace them promptly if they become hard or dirty. It is recommended to replace them every three months.8. Inspection and maintenance of the water circuit. The water pipes in the water circuit are prone to clogging and leakage. Regularly check for leaks or blockages. If found, remove them promptly or notify the manufacturer.
    อ่านเพิ่มเติม
  • 2 เหตุผลที่ห้องทดสอบอุณหภูมิและความชื้นคงที่ไม่ทำความเย็น 2 เหตุผลที่ห้องทดสอบอุณหภูมิและความชื้นคงที่ไม่ทำความเย็น
    Jun 10, 2025
    เหตุผลหนึ่ง 1. เนื่องจากอุณหภูมิของห้องทดสอบอุณหภูมิและความชื้นคงที่ไม่สามารถรักษาไว้ได้ ให้สังเกตว่าคอมเพรสเซอร์ทำความเย็นสามารถเริ่มทำงานได้หรือไม่เมื่อห้องทดสอบกำลังทำงาน และคอมเพรสเซอร์สามารถเริ่มทำงานได้หรือไม่เมื่ออุปกรณ์ทดสอบสภาพแวดล้อมกำลังทำงาน โดยระบุว่าวงจรจากแหล่งจ่ายไฟหลักไปยังคอมเพรสเซอร์แต่ละตัวเป็นปกติและระบบไฟฟ้าไม่มีปัญหา2. ระบบไฟฟ้าไม่มีความผิดปกติ ให้ตรวจสอบระบบทำความเย็นต่อไป ก่อนอื่น ให้ตรวจสอบว่าแรงดันไอเสียและแรงดันดูดของคอมเพรสเซอร์อุณหภูมิต่ำ (R23) ของชุดทำความเย็นทั้งสองชุดต่ำกว่าค่าปกติหรือไม่ และแรงดันดูดอยู่ในสถานะสุญญากาศหรือไม่ ซึ่งบ่งชี้ว่าปริมาณการทำความเย็นของชุดทำความเย็นหลักไม่เพียงพอ3. แตะท่อไอเสียและท่อดูดของคอมเพรสเซอร์ R23 ด้วยมือ พบว่าอุณหภูมิของท่อไอเสียไม่สูง และอุณหภูมิของท่อดูดก็ไม่ต่ำ (ไม่มีน้ำแข็งเกาะ) ซึ่งยังบ่งบอกว่าสารทำความเย็น R23 ในเครื่องโฮสต์ไม่เพียงพออีกด้วยเหตุผลอื่น: 1. สาเหตุของความล้มเหลวยังไม่ได้รับการระบุ และต้องมีการยืนยันเพิ่มเติมร่วมกับกระบวนการควบคุมของห้องทดสอบอุณหภูมิและความชื้นคงที่ ห้องทดสอบมีชุดทำความเย็นสองชุดหน่วยหนึ่งคือหน่วยหลัก และอีกหน่วยหนึ่งคือหน่วยเสริม เมื่ออัตราการทำความเย็นสูง หน่วยทั้งสองจะทำงานพร้อมกันในช่วงเริ่มต้นของเฟสการรักษาอุณหภูมิ เมื่ออุณหภูมิคงที่ หน่วยเสริมจะหยุด และหน่วยหลักจะรักษาอุณหภูมิ หากสารทำความเย็น R23 รั่วออกจากหน่วยหลัก ประสิทธิภาพการทำความเย็นจะลดลงอย่างมาก ในระหว่างกระบวนการทำความเย็น หน่วยทั้งสองจะทำงานพร้อมกัน ทำให้อุณหภูมิคงที่และอัตราการทำความเย็นลดลงอย่างค่อยเป็นค่อยไป ในระยะฉนวน หากหน่วยเสริมหยุดทำงาน หน่วยหลักจะสูญเสียฟังก์ชันการทำความเย็น ทำให้ปริมาณอากาศภายในห้องทดสอบเพิ่มขึ้นช้าๆ เมื่ออุณหภูมิถึงระดับหนึ่ง ระบบควบคุมจะเปิดใช้งานหน่วยเสริมเพื่อให้เย็นลง หลังจากนั้น หน่วยเสริมจะหยุดอีกครั้ง สาเหตุของความล้มเหลวในการผลิตได้รับการระบุว่าเกิดจากสารทำความเย็นอุณหภูมิต่ำ (R23) รั่วออกจากหน่วยหลัก เมื่อตรวจสอบระบบทำความเย็นเพื่อหาจุดรั่ว พบรอยแตกร้าวที่ก้านวาล์วของโซลินอยด์วาล์วบายพาสก๊าซร้อน ซึ่งมีความยาวประมาณ 1 ซม. หลังจากเปลี่ยนโซลินอยด์วาล์วและเติมสารทำความเย็นใหม่ ระบบก็กลับมาทำงานได้ตามปกติ การวิเคราะห์นี้แสดงให้เห็นว่าการวินิจฉัยข้อบกพร่องนั้นใช้แนวทางแบบทีละขั้นตอน โดยเริ่มจากแง่มุม "ภายนอก" แล้วค่อยไปด้านใน จากนั้นจึงเน้นที่ "ไฟฟ้า" และสุดท้ายที่ "การทำความเย็น" ความเข้าใจอย่างถ่องแท้เกี่ยวกับหลักการและกระบวนการทำงานในห้องทดสอบถือเป็นสิ่งสำคัญสำหรับการวินิจฉัยข้อบกพร่องอย่างแม่นยำ
    อ่านเพิ่มเติม
  • จุดสำคัญในการเลือกห้องทดสอบอุณหภูมิสูงและต่ำ จุดสำคัญในการเลือกห้องทดสอบอุณหภูมิสูงและต่ำ
    Jun 06, 2025
    8 ประเด็นสำคัญในการเลือก ห้องทดสอบอุณหภูมิสูงและต่ำ:1. ไม่ว่าจะเลือกสำหรับห้องทดสอบอุณหภูมิสูงและต่ำหรืออุปกรณ์ทดสอบอื่นๆ ก็ตาม จะต้องเป็นไปตามเงื่อนไขอุณหภูมิที่ระบุในข้อกำหนดการทดสอบ2. เพื่อให้แน่ใจว่าอุณหภูมิในห้องทดสอบสม่ำเสมอ สามารถเลือกโหมดการหมุนเวียนอากาศแบบบังคับหรือการหมุนเวียนอากาศแบบไม่บังคับได้ตามการกระจายความร้อนของตัวอย่าง3.ระบบทำความร้อนหรือทำความเย็นของห้องทดสอบอุณหภูมิสูงและต่ำไม่ควรมีผลต่อตัวอย่าง4. ห้องทดสอบควรสะดวกสำหรับชั้นวางตัวอย่างที่เกี่ยวข้องเพื่อวางตัวอย่าง และชั้นวางตัวอย่างจะไม่เปลี่ยนคุณสมบัติเชิงกลเนื่องจากการเปลี่ยนแปลงอุณหภูมิที่สูงและต่ำ5. ห้องทดสอบอุณหภูมิสูงและต่ำควรมีมาตรการป้องกัน เช่น มีหน้าต่างและไฟส่องสว่างสำหรับสังเกตการณ์ การตัดไฟ การป้องกันอุณหภูมิเกิน อุปกรณ์แจ้งเตือนต่างๆ6. มีฟังก์ชั่นการตรวจสอบระยะไกลตามความต้องการของลูกค้าหรือไม่7. ห้องทดสอบจะต้องมีอุปกรณ์นับอัตโนมัติ ไฟแสดงสถานะและบันทึก ระบบปิดเครื่องอัตโนมัติและอุปกรณ์เครื่องมืออื่นๆ เมื่อดำเนินการทดสอบแบบวงจร และจะต้องมีฟังก์ชันการบันทึกและการแสดงผลที่ดี8. ตามอุณหภูมิของตัวอย่าง มีวิธีการวัด 2 วิธี คือ เซ็นเซอร์อุณหภูมิลมบนและลมล่าง สามารถเลือกตำแหน่งและโหมดควบคุมของเซ็นเซอร์ควบคุมอุณหภูมิและความชื้นในห้องทดสอบอุณหภูมิสูงและต่ำได้ตามความต้องการในการทดสอบผลิตภัณฑ์ของลูกค้า เพื่อเลือกอุปกรณ์ที่เหมาะสม
    อ่านเพิ่มเติม
  • ข้อมูลทั้งหมดเกี่ยวกับห้องวัดอุณหภูมิ: คืออะไร และทำงานอย่างไร?
    Mar 03, 2025
    เพื่อนร่วมห้องแล็ปซึ่งเรามุ่งมั่นที่จะส่งมอบอุปกรณ์ทดสอบสิ่งแวดล้อมคุณภาพสูงที่ตอบสนองความต้องการที่หลากหลายของอุตสาหกรรมต่างๆ ในฐานะผู้นำในอุตสาหกรรม เราจึงเสนอผลิตภัณฑ์หลากหลายประเภทที่รับประกันการทดสอบที่เชื่อถือได้และการรับรองคุณภาพสำหรับการดำเนินงานของคุณ ห้องทดสอบอุณหภูมิของเราสามารถทำงานได้ในช่วงอุณหภูมิ 0°C ถึง + 200°C และความชื้นสัมพัทธ์ 5% ถึง 98% ห้องทดสอบเหล่านี้ให้เงื่อนไขการทดสอบที่เสถียรและยาวนาน จึงสอดคล้องกับแนวทาง ICH Q1A และเหมาะสำหรับการใช้งานที่หลากหลาย เรียนรู้เพิ่มเติมเกี่ยวกับห้องทดสอบความร้อนด้านล่าง และดูว่าห้องเหล่านี้สามารถช่วยให้แน่ใจว่ามีอายุการใช้งานยาวนานและความน่าเชื่อถือสำหรับความต้องการการทดสอบทั้งหมดของคุณได้อย่างไร ห้องวัดอุณหภูมิคืออะไร?ห้องวัดอุณหภูมิซึ่งมักเรียกแทนกันว่าห้องควบคุมอุณหภูมิ ซึ่งเป็นตู้หุ้มแบบพิเศษที่ออกแบบมาเพื่อสร้างสภาพแวดล้อมควบคุมอุณหภูมิห้องเหล่านี้ช่วยให้จำลองอุณหภูมิได้อย่างแม่นยำ ตั้งแต่อุณหภูมิเย็นจัดไปจนถึงอุณหภูมิร้อนจัด เพื่อให้มีการตั้งค่าที่เสถียร ซึ่งนักวิจัยสามารถทดสอบผลิตภัณฑ์หรือวัสดุในด้านความยืดหยุ่น ความทนทาน และประสิทธิภาพโดยรวมบทบาทของตู้ควบคุมอุณหภูมิมีบทบาทสำคัญอย่างยิ่งในขั้นตอนการวิจัยและการพัฒนาในอุตสาหกรรมต่างๆ ตู้ควบคุมอุณหภูมิทำให้ผลิตภัณฑ์ต้องอยู่ภายใต้สภาวะความร้อนต่างๆ ที่อาจเกิดขึ้นในโลกแห่งความเป็นจริงการทดสอบจำลองนี้มีความจำเป็นต่อกระบวนการรับรองคุณภาพ เพื่อให้แน่ใจว่าผลิตภัณฑ์เป็นไปตามมาตรฐานความปลอดภัยและประสิทธิภาพที่ต้องการห้องวัดอุณหภูมิสามารถจำลองสถานการณ์อุณหภูมิต่างๆ ได้ ทำให้ผู้ผลิตและนักวิจัยสามารถระบุข้อบกพร่องในการออกแบบที่อาจเกิดขึ้นได้แต่เนิ่นๆ ช่วยประหยัดทั้งเวลาและทรัพยากรในระยะยาว ห้องควบคุมอุณหภูมิทำงานอย่างไร?ห้องควบคุมอุณหภูมิเป็นชุดประกอบที่ซับซ้อนของส่วนประกอบต่างๆ ที่สร้างสภาพแวดล้อมอุณหภูมิที่ควบคุมได้ โดยแกนหลักของห้องนี้คือระบบทำความร้อนและทำความเย็นที่สามารถสร้างอุณหภูมิที่ต้องการได้ ระบบเหล่านี้มักใช้เครื่องทำความร้อนไฟฟ้าในการทำความร้อน และใช้คอมเพรสเซอร์และสารทำความเย็นร่วมกันในการทำความเย็นฉนวนกันความร้อนมีความสำคัญอย่างยิ่งต่อการรักษาสภาพแวดล้อมภายในห้อง วัสดุเฉพาะทางช่วยให้มั่นใจได้ว่าการเปลี่ยนแปลงอุณหภูมิจะถูกควบคุมไว้อย่างดี การจัดการการไหลเวียนของอากาศก็เป็นสิ่งสำคัญเช่นกัน พัดลมและท่อจะหมุนเวียนอากาศเพื่อสร้างสภาวะที่สม่ำเสมอทั่วทั้งห้อง“สมอง” ของห้องควบคุมอุณหภูมิคือตัวควบคุมและเซ็นเซอร์ ซึ่งทำหน้าที่ตรวจสอบอุณหภูมิและให้แน่ใจว่าอุณหภูมิยังคงอยู่ในพารามิเตอร์ที่กำหนดห้องควบคุมอุณหภูมิจำนวนมากใช้ตัวควบคุม PID (Proportional-Integral-Derivative) เพื่อรักษาความแม่นยำของอุณหภูมิ ตัวควบคุม PID จะคำนวณความแตกต่างระหว่างอุณหภูมิที่ต้องการและอุณหภูมิปัจจุบันอย่างต่อเนื่อง โดยปรับระบบทำความร้อนและทำความเย็นแบบเรียลไทม์เพื่อรักษาอุณหภูมิให้อยู่ในช่วงที่กำหนดไว้ล่วงหน้าส่วนประกอบทั้งหมดเหล่านี้มารวมกันเพื่อขับเคลื่อนระบบที่สามารถจำลองสภาวะอุณหภูมิในช่วงกว้าง ทำให้ห้องควบคุมอุณหภูมิเป็นเครื่องมือที่มีคุณค่าอย่างยิ่งในกระบวนการพัฒนาผลิตภัณฑ์และการรับรองคุณภาพ ห้องวัดอุณหภูมิ: อุตสาหกรรมและการใช้งานห้องควบคุมอุณหภูมิเป็นเครื่องมืออเนกประสงค์ที่สามารถใช้งานได้หลากหลายอุตสาหกรรม บทบาทในการจำลองสภาวะอุณหภูมิต่างๆ ทำให้เครื่องมือเหล่านี้มีความจำเป็นสำหรับการวิจัย พัฒนา และรับรองคุณภาพอุตสาหกรรมยานยนต์ในภาคยานยนต์ ห้องทดสอบอุณหภูมิจะทดสอบส่วนประกอบต่างๆ เช่น เครื่องยนต์ แบตเตอรี่ และระบบ HVAC การทดสอบเหล่านี้ช่วยให้ผู้ผลิตมั่นใจได้ว่ายานพาหนะสามารถทนต่อสภาพอากาศที่รุนแรง ไม่ว่าจะเป็นความหนาวเย็นของฤดูหนาวหรือความร้อนระอุของทะเลทรายที่แผดเผาอุตสาหกรรมอิเล็กทรอนิกส์สำหรับอุปกรณ์อิเล็กทรอนิกส์ ห้องควบคุมอุณหภูมิช่วยให้มั่นใจได้ว่าอุปกรณ์ต่างๆ เช่น สมาร์ทโฟน แล็ปท็อป และอุปกรณ์อื่นๆ จะทำงานได้อย่างมีประสิทธิภาพในอุณหภูมิต่างๆ ตัวอย่างเช่น การทดสอบสภาพความชื้น มีความสำคัญอย่างยิ่งต่อความพึงพอใจและความปลอดภัยของผู้บริโภค โดยช่วยให้มั่นใจได้ว่าอุปกรณ์จะไม่ล้มเหลวเมื่อเผชิญกับสภาวะที่รุนแรงอุตสาหกรรมการแพทย์/เภสัชกรรมในภาคการแพทย์และเภสัชกรรม ห้องทดสอบความร้อนมีความจำเป็นสำหรับการทดสอบเสถียรภาพและอายุการเก็บรักษาของยาและความน่าเชื่อถือของอุปกรณ์ทางการแพทย์ ตั้งแต่วัคซีนไปจนถึงเครื่องกระตุ้นหัวใจ การทดสอบเสถียรภาพช่วยให้มั่นใจได้ว่าผลิตภัณฑ์ที่สำคัญเหล่านี้ทำงานได้อย่างปลอดภัยและมีประสิทธิภาพอุตสาหกรรมการบินและอวกาศภาคการบินและอวกาศมักใช้ห้องทดสอบอุณหภูมิเพื่อทดสอบส่วนประกอบต่างๆ ที่จะทนทานต่อสภาวะที่รุนแรงในอวกาศหรือการบินในระดับความสูง ผู้ผลิตเครื่องบินจะต้องทดสอบทุกอย่างตั้งแต่วัสดุที่ใช้ในตัวเครื่องบินไปจนถึงอุปกรณ์อิเล็กทรอนิกส์ในระบบดาวเทียมเพื่อให้มั่นใจถึงความยืดหยุ่น ความน่าเชื่อถือ และปลอดภัย ประเภทของการทดสอบที่ดำเนินการในห้องความร้อนห้องทดสอบความร้อนมีความอเนกประสงค์และสามารถทำการทดสอบได้หลากหลายรูปแบบซึ่งจำลองสภาพแวดล้อมที่แตกต่างกัน การทดสอบที่พบบ่อยที่สุด ได้แก่:การเปลี่ยนแปลงอุณหภูมิ: การทดสอบนี้ให้ผู้ทดสอบสัมผัสกับอุณหภูมิที่แตกต่างกัน ซึ่งสลับไปมาระหว่างอากาศเย็นและร้อน เพื่อประเมินความสามารถในการฟื้นตัวและระบุจุดอ่อนที่อาจเกิดขึ้นการช็อกจากความร้อน: ในกรณีนี้ ผลิตภัณฑ์จะต้องประสบกับการเปลี่ยนแปลงอุณหภูมิอย่างกะทันหันเพื่อประเมินความสามารถในการทนต่อความผันผวนของอุณหภูมิที่ฉับพลัน ซึ่งเป็นสาเหตุที่มักทำให้มีอุปกรณ์จำนวนมากที่เสียหายการทดสอบอุณหภูมิสูง: การทดสอบนี้ประเมินความสามารถของบุคคลในการทำงานภายใต้อุณหภูมิที่สูงอย่างมาก เป็นเวลานานการทดสอบที่อุณหภูมิต่ำ: การทดสอบนี้ใช้เพื่อประเมินว่าผลิตภัณฑ์สามารถทำงานได้ดีเพียงใดในอุณหภูมิที่เย็นจัด ซึ่งมักจะเป็นอุณหภูมิเยือกแข็งหรือต่ำกว่าการทดสอบอุณหภูมิและความชื้น: การทดสอบนี้รวมตัวแปรทั้งอุณหภูมิและความชื้นเข้าด้วยกัน แม้ว่าห้องทดสอบอุณหภูมิจะเน้นที่สภาวะอุณหภูมิเป็นหลัก แต่ห้องทดสอบเหล่านี้ก็มักจะรวมการตั้งค่าความชื้นเข้าไปได้ในระดับหนึ่ง นี่คือจุดที่ห้องทดสอบความชื้นแตกต่างจากห้องทดสอบความชื้นซึ่งควบคุมระดับความชื้นเป็นหลักหากคุณกำลังมองหาห้องควบคุมอุณหภูมิและความชื้น Lab-companion นำเสนอ ห้องพิเศษ ที่มอบสิ่งที่ดีที่สุดของทั้งสองโลก สำรวจห้องวัดอุณหภูมิของ LAB-COMPANIONเมื่อพูดถึงความน่าเชื่อถือและประสิทธิภาพ แคตตาล็อกผลิตภัณฑ์ของเรามีความโดดเด่นด้วยเหตุผลหลายประการดังต่อไปนี้:การทดสอบที่รวดเร็ว: ด้วยระบบทำความร้อนและทำความเย็นขั้นสูง ห้องทดสอบของเราได้รับการออกแบบสำหรับการเปลี่ยนแปลงอุณหภูมิอย่างรวดเร็ว ช่วยให้ทดสอบได้รวดเร็วยิ่งขึ้น โดยไม่กระทบต่อความแม่นยำของผลลัพธ์ผลลัพธ์ที่เชื่อถือได้: ห้องทดสอบมีเซ็นเซอร์และระบบควบคุมอันทันสมัย ​​เพื่อให้แน่ใจว่าคุณจะได้รับข้อมูลที่สม่ำเสมอและเชื่อถือได้ตลอดกระบวนการทดสอบความคุ้มทุน: การลงทุนในห้องตรวจอุณหภูมิคุณภาพสูงเช่นที่เรานำเสนอสามารถลดต้นทุนการทดสอบในระยะยาวได้อย่างมาก ความทนทานและความต้องการในการบำรุงรักษาต่ำทำให้ห้องตรวจอุณหภูมิเป็นตัวเลือกที่คุ้มทุนสำหรับองค์กรใดๆการตั้งค่าที่ปรับแต่งได้: Lab-companion มอบการปรับแต่งในระดับสูง ช่วยให้คุณปรับแต่งสภาพแวดล้อมการทดสอบตามความต้องการเฉพาะของผลิตภัณฑ์ของคุณได้ ช่วยเพิ่มความแม่นยำของการทดสอบของคุณมากยิ่งขึ้น การทำความเข้าใจข้อดีข้อเสียของห้องวัดอุณหภูมิถือเป็นสิ่งสำคัญสำหรับทุกคนที่เกี่ยวข้องกับการพัฒนาผลิตภัณฑ์ การวิจัย หรือการรับประกันคุณภาพในอุตสาหกรรมต่างๆห้องทดสอบเหล่านี้มีบทบาทสำคัญในการจำลองสภาพแวดล้อมที่แตกต่างกัน ช่วยให้องค์กรต่างๆ สามารถทดสอบผลิตภัณฑ์ของตนอย่างเข้มงวดในด้านความปลอดภัย ความน่าเชื่อถือ และความทนทาน ตั้งแต่ยานยนต์และอิเล็กทรอนิกส์ไปจนถึงอวกาศและยา การใช้งานนั้นมีความหลากหลายและมีความสำคัญอย่างยิ่งหากคุณต้องการยกระดับกระบวนการทดสอบของคุณ คุณต้องไม่มองข้ามคุณค่าของห้องวัดอุณหภูมิชั้นนำติดต่อเราได้ที่ด้านล่างของหน้านี้เพื่อข้อมูลเพิ่มเติม  
    อ่านเพิ่มเติม

ฝากข้อความ

ฝากข้อความ
หากคุณสนใจผลิตภัณฑ์ของเราและต้องการทราบรายละเอียดเพิ่มเติม โปรดฝากข้อความไว้ที่นี่ เราจะตอบกลับคุณโดยเร็วที่สุด
ส่ง

บ้าน

สินค้า

วอทส์แอพพ์

ติดต่อเรา