แบนเนอร์
บ้าน

ห้องทดสอบอุณหภูมิและความชื้น

ห้องทดสอบอุณหภูมิและความชื้น

  • JESD22-A101B Compliant Environmental Testing Solution | Lab Companion Temperature & Humidity Test Chamber for Semiconductor Moisture Resistance Validation
    Aug 18, 2026
    1. Industry Overview: JESD22-A101B Steady-State Humidity Testing for Semiconductor Reliability JESD22-A101B is a globally recognized JEDEC standard for steady-state temperature and humidity reliability testing. It defines standardized test conditions, operational procedures, and failure criteria for semiconductor packaged devices under high-temperature and high-humidity environments. This specification is widely adopted for reliability qualification of IC chips, power devices, and various packaged semiconductors across the global semiconductor industry. Semiconductor plastic packages, lead frames, encapsulation adhesives, and passivation layers are highly susceptible to moisture penetration. Under prolonged high-temperature and high-humidity stress, moisture ingress causes package hydrolysis, metal lead corrosion, interface delamination, and internal circuit oxidation. These failures lead to increased leakage current, performance degradation, and complete device malfunction in field applications. JESD22-A101B testing simulates real-world humid storage and operating conditions in a controlled laboratory environment. It effectively identifies semiconductors with insufficient moisture resistance before mass production, significantly reducing field failure risks. Today, JESD22-A101B has become a mandatory reliability item for mainstream semiconductor packaging, testing, and component manufacturing factories worldwide. Lab Companion offers fully JESD22-A101B compliant temperature and humidity test chambers. We provide a complete overseas testing solution including standard-matched hardware, remote test program calibration, and customized sample fixturing to support semiconductor labs in conducting accurate, repeatable moisture reliability validation. 2. Key Challenges in JESD22-A101B Semiconductor Humidity Testing Semiconductor packages are compact and precision-structured. JESD22-A101B requires extremely strict control over chamber uniformity, long-term operational stability, and humidity consistency. Ordinary environmental test equipment frequently fails to meet standard requirements, causing invalid tests and inconsistent data. 2.1 Poor Chamber Uniformity Causes Unrepeatable Batch Test Results JESD22-A101B specifies strict temperature and humidity distribution tolerances within the test chamber. Conventional chambers suffer from defective airflow and humidification system designs, creating obvious temperature and humidity gradients. Devices placed in different positions receive inconsistent environmental stress. Weak uniformity leads to undetected latent defects, discrete test data, and non-compliant qualification results. 2.2 Long-Duration Testing Humidity Drift Leads to Test Failure JESD22-A101B tests typically require hundreds of hours of continuous unattended operation. Most general-purpose chambers cannot maintain stable humidity output during long-cycle high-humidity aging. Humidity drift and fluctuation deviate from standard set points, resulting in invalid tests, wasted samples, and increased laboratory time costs. 2.3 Lack of Semiconductor-Specific Fixtures Affects Test Validity Semiconductors include diverse package types such as BGA, QFP, SOP, and power modules. Standard generic shelves provide no positioning protection. Stacked placement causes lead deformation and physical damage. Improper loading also blocks internal airflow, further deteriorating chamber uniformity and compromising test accuracy. 2.4 High Humidity Operation Accelerates Equipment Aging & Technical Support Gaps Long-term high-temperature and high-humidity operation continuously erodes chamber interiors, humidifying components, and sensors. For overseas users, local on-site maintenance is unavailable with ordinary equipment brands. Sensor drift, water circuit faults, and system deviations cannot be resolved promptly, causing test suspension and project delays. 3. Lab Companion Hardware Advantages for Full JESD22-A101B Compliance Lab Companion temperature and humidity chambers are fully optimized and calibrated to meet JESD22-A101B standard requirements. All core control systems, airflow structures, and operational logic are tailored for semiconductor long-term humidity aging tests. 3.1 High Precision & Excellent Uniformity for Batch Testing The chamber supports a temperature range of -70℃ ~ +150℃ and a humidity range of 20%RH ~ 98%RH, with temperature accuracy of ±0.5℃ and humidity accuracy of ±2.5%RH. The optimized circulating airflow system ensures uniform temperature and humidity distribution across the entire workspace. Even in full-load batch testing, all DUTs (devices under test) receive identical environmental stress, ensuring consistent and repeatable test data. The equipment supports continuous long-term aging with minimal parameter drift, fully complying with JESD22-A101B long-cycle test specifications. 3.2 Programmable Controller for Standard Test Recipe Storage Equipped with an intelligent touchscreen programmable controller, the chamber supports full parameter configuration and storage of standard JESD22-A101B temperature, humidity, and dwell-time recipes. Users can save customized test procedures for different semiconductor packages and recall one-click startup for subsequent tests. This eliminates repetitive manual setting errors and greatly improves laboratory testing efficiency. 3.3 Custom Semiconductor Fixtures for Safe & Accurate Loading Lab Companion provides customized non-blocking fixture trays for BGA, QFP, SOP, and power module devices. The dedicated positioning structure prevents lead collision and mechanical damage during testing. The hollowed-out design ensures unobstructed internal airflow, enabling full environmental coverage for every device and eliminating placement-induced test deviations. 4. JESD22-A101B Validation for Full-Range Semiconductor Devices Lab Companion solutions support standardized moisture resistance qualification for mainstream semiconductor components: • IC Chips (BGA/QFP): Evaluate encapsulation moisture permeability and screen package delamination risks. • Power Modules: Verify sealing tightness and lead corrosion resistance under continuous high-humidity conditions. • Small Discrete Devices: Screen hidden defects in adhesive layers and passivation layers via batch steady-state humidity aging. All tests strictly follow JESD22-A101B standard conditions and duration requirements. Post-test validation includes electrical performance testing, visual inspection, and acoustic scanning analysis to identify moisture-induced failures. This mature qualification solution has been widely adopted by professional semiconductor testing laboratories. 5. Global Remote Technical Support & Complete Solution Service To serve global clients efficiently, Lab Companion provides full-process online remote technical support for overseas users (no local on-site service), ensuring stable and compliant test operation worldwide. 5.1 Professional Remote Guidance & Troubleshooting Our professional engineering team provides one-stop remote support including JESD22-A101B recipe debugging, parameter calibration, fixture scheme confirmation, daily equipment operation guidance, and remote fault diagnosis. Fast online response effectively avoids test suspension and project delay caused by equipment parameter deviation or operational errors. 5.2 Standard Compliance Technical Consulting We provide professional standard interpretation and process guidance for new-built reliability laboratories. Our team assists users in establishing standardized pre-test and post-test performance comparison processes to ensure all test procedures fully meet JEDEC certification and audit requirements. 5.3 Full-Spectrum Environmental Test Equipment Portfolio Beyond JESD22-A101B humidity testing, Lab Companion offers a full lineup of self-developed environmental test equipment, including thermal shock chambers, rapid temperature change chambers, and walk-in environmental rooms. We support comprehensive semiconductor reliability tests such as temperature cycling, thermal shock, and ESS screening, providing global clients with one-stop environmental qualification solutions. 6. Conclusion Moisture-induced package delamination, metal corrosion, and performance degradation are critical failure modes for semiconductor devices. As the core JEDEC standard for moisture resistance qualification, JESD22-A101B demands high-precision, high-stability, and high-uniformity test equipment. Lab Companion temperature and humidity chambers deliver wide-range precise control, excellent chamber uniformity, long-term operational stability, programmable standard recipes, and customized semiconductor fixturing. Combined withglobal professional remote technical support, our standardized JESD22-A101B testing solution helps overseas semiconductor manufacturers and testing labs achieve accurate, repeatable, and compliant moisture reliability validation, ensuring consistent product quality and field operational reliability.
    อ่านเพิ่มเติม
  • IEC 68-2-66 วิธีทดสอบ Cx: ความร้อนชื้นแบบคงตัว (ไออิ่มตัวที่ไม่ได้รับแรงดัน)
    Apr 18, 2025
    คำนำ วัตถุประสงค์ของวิธีการทดสอบนี้คือเพื่อจัดทำขั้นตอนมาตรฐานสำหรับการประเมินความต้านทานของผลิตภัณฑ์ไฟฟ้าขนาดเล็ก (ส่วนใหญ่เป็นส่วนประกอบที่ไม่ปิดสนิท) โดยใช้ห้องทดสอบอุณหภูมิสูงและต่ำและสภาพแวดล้อมที่มีความชื้น ขอบเขต วิธีทดสอบนี้ใช้กับการทดสอบความร้อนชื้นเร่งของผลิตภัณฑ์ไฟฟ้าขนาดเล็ก ข้อจำกัด วิธีนี้ไม่เหมาะสำหรับการตรวจสอบผลกระทบภายนอกของตัวอย่าง เช่น การกัดกร่อนหรือการเสียรูป ขั้นตอนการทดสอบ1. การตรวจสอบก่อนการทดสอบ ชิ้นงานจะต้องผ่านการตรวจสอบด้วยสายตา มิติ และการทำงาน ตามที่กำหนดไว้ในมาตรฐานที่เกี่ยวข้อง 2. การวางตัวอย่าง ตัวอย่างจะต้องวางไว้ในห้องทดสอบภายใต้สภาวะห้องปฏิบัติการที่มีอุณหภูมิ ความชื้นสัมพัทธ์ และความดันบรรยากาศ 3. การใช้แรงดันไบอัส (ถ้ามี) หากจำเป็นต้องใช้แรงดันไฟฟ้าอคติตามมาตรฐานที่เกี่ยวข้อง ควรใช้เฉพาะเมื่อตัวอย่างถึงสมดุลความร้อนและความชื้นแล้วเท่านั้น 4. การเพิ่มอุณหภูมิและความชื้น อุณหภูมิจะต้องเพิ่มขึ้นถึงค่าที่กำหนด ในช่วงเวลานี้ อากาศในห้องจะถูกแทนที่โดยไอน้ำ อุณหภูมิและความชื้นสัมพัทธ์จะต้องไม่เกินขีดจำกัดที่กำหนด จะต้องไม่เกิดการควบแน่นบนตัวอย่าง การทำให้อุณหภูมิและความชื้นคงที่ต้องเสร็จภายใน 1.5 ชั่วโมง หากระยะเวลาการทดสอบเกิน 48 ชั่วโมงและไม่สามารถทำให้อุณหภูมิคงที่ได้ภายใน 1.5 ชั่วโมง จะต้องทำให้อุณหภูมิคงที่ภายใน 3.0 ชั่วโมง 5. การดำเนินการทดสอบ รักษาอุณหภูมิ ความชื้น และแรงดันที่ระดับที่กำหนดตามมาตรฐานที่เกี่ยวข้อง ระยะเวลาการทดสอบจะเริ่มต้นเมื่อถึงสภาวะคงที่ 6. การฟื้นฟูหลังการทดสอบ หลังจากระยะเวลาทดสอบที่กำหนด สภาพห้องจะต้องกลับสู่สภาพบรรยากาศมาตรฐาน (1–4 ชั่วโมง) อุณหภูมิและความชื้นจะต้องไม่เกินขีดจำกัดที่กำหนดในระหว่างการฟื้นตัว (อนุญาตให้มีการทำความเย็นตามธรรมชาติ) ควรปล่อยให้ตัวอย่างคงตัวเต็มที่ก่อนดำเนินการจัดการเพิ่มเติม 7. การวัดในการทดสอบ (ถ้าจำเป็น) การตรวจสอบทางไฟฟ้าหรือทางกลในระหว่างการทดสอบจะต้องดำเนินการโดยไม่เปลี่ยนแปลงเงื่อนไขการทดสอบ ห้ามนำตัวอย่างออกจากห้องก่อนที่จะนำกลับคืน 8. การตรวจสอบหลังการทดสอบภายหลังการฟื้นตัว (2–24 ชั่วโมง ภายใต้สภาวะมาตรฐาน) ตัวอย่างจะต้องผ่านการตรวจสอบด้วยสายตา ขนาด และการทำงานตามมาตรฐานที่เกี่ยวข้อง - เงื่อนไขการทดสอบเว้นแต่จะระบุไว้เป็นอย่างอื่น เงื่อนไขการทดสอบจะประกอบด้วยการรวมกันของอุณหภูมิและระยะเวลาตามที่ระบุไว้ในตารางที่ 1 - การตั้งค่าการทดสอบ1. ข้อกำหนดของห้อง เซ็นเซอร์วัดอุณหภูมิจะต้องตรวจสอบอุณหภูมิในห้อง ควรไล่อากาศในห้องด้วยไอน้ำก่อนการทดสอบ ห้ามให้คอนเดนเสทหยดลงบนตัวอย่าง 2. วัสดุห้องผนังห้องจะต้องไม่ทำให้คุณภาพของไอลดลงหรือทำให้เกิดการกัดกร่อนของตัวอย่าง 3. ความสม่ำเสมอของอุณหภูมิความคลาดเคลื่อนรวม (ความแปรผันเชิงพื้นที่ ความผันผวน และข้อผิดพลาดในการวัด): ±2°C เพื่อรักษาความทนทานต่อความชื้นสัมพัทธ์ (±5%) ความแตกต่างของอุณหภูมิระหว่างสองจุดในห้องจะต้องลดลงให้น้อยที่สุด (≤1.5°C) แม้จะอยู่ระหว่างการเพิ่มขึ้น/ลดลงก็ตาม 4. การวางตัวอย่างตัวอย่างต้องไม่กีดขวางการไหลของไอ ห้ามสัมผัสความร้อนโดยตรง หากใช้อุปกรณ์ติดตั้ง จะต้องลดการนำความร้อนและความจุความร้อนให้เหลือน้อยที่สุดเพื่อหลีกเลี่ยงการกระทบต่อสภาวะการทดสอบ วัสดุติดตั้งจะต้องไม่ทำให้เกิดการปนเปื้อนหรือการกัดกร่อน 3. คุณภาพน้ำ ใช้น้ำกลั่นหรือน้ำที่ผ่านการดีไอออนไนซ์ร่วมกับ: ค่าต้านทาน ≥0.5 MΩ·cm ที่ 23°C pH 6.0–7.2 ที่ 23°C ควรทำความสะอาดเครื่องเพิ่มความชื้นในห้องโดยการขัดถูก่อนเติมน้ำ - ข้อมูลเพิ่มเติมตารางที่ 2 แสดงอุณหภูมิไอน้ำอิ่มตัวที่สอดคล้องกับอุณหภูมิแห้ง (100–123°C) แผนผังของอุปกรณ์ทดสอบภาชนะเดี่ยวและภาชนะคู่แสดงในรูปที่ 1 และ 2 - ตารางที่ 1: ความรุนแรงของการทดสอบ| อุณหภูมิ (°C) | RH (%) | ระยะเวลา (ชม., -0/+2) | อุณหภูมิความชื้นสัมพัทธ์เวลา (ชั่วโมง, -0/+2)±2℃±5%ⅠⅡⅢ110859619240812085489619213085244896หมายเหตุ: ความดันไอที่ 110°C, 120°C และ 130°C จะต้องเป็น 0.12 MPa, 0.17 MPa และ 0.22 MPa ตามลำดับ - ตารางที่ 2: อุณหภูมิไอน้ำอิ่มตัวเทียบกับความชื้นสัมพัทธ์ (ช่วงอุณหภูมิแห้ง: 100–123°C)อุณหภูมิอิ่มตัว (℃)ญาติความชื้น(%RH)100%95%90%85%80%75%70%65%60%55%50%อุณหภูมิแห้ง (℃) 100 100.098.697.195.593.992.190.388.486.384.181.7101 101.099.698.196.594.893.191.289.387.285.082.6102 102.0100.699.097.595.894.092.290.288.185.983.5103 103.0101.5100.098.496.895.093.192.189.086.884.3104 104.0102.5101.099.497.795.994.192.190.087.785.2105 105.0103.5102.0100.498.796.995.093.090.988.686.1106 106.0104.5103.0101.399.697.896.093.991.889.587.0107 107.0105.5103.9102.3100.698.896.994.992.790.487.9108 108.0106.5104.9103.3101.699.897.895.893.691.388.8109 109.0107.5105.9104.3102.5100.798.896.794.592.289.7110 110.0108.5106.9105.2103.5101.799.797.795.593.190.6(คอลัมน์เพิ่มเติมสำหรับ %RH และอุณหภูมิอิ่มตัวจะตามมาตามตารางเดิม) - ชี้แจงเงื่อนไขสำคัญ:“ไออิ่มตัวที่ไม่ได้รับแรงดัน”: สภาพแวดล้อมที่มีความชื้นสูงโดยไม่ต้องใช้แรงดันจากภายนอก “สภาวะคงที่”: สภาวะคงที่คงไว้ตลอดการทดสอบ
    อ่านเพิ่มเติม

ฝากข้อความ

ฝากข้อความ
หากคุณสนใจผลิตภัณฑ์ของเราและต้องการทราบรายละเอียดเพิ่มเติม โปรดฝากข้อความไว้ที่นี่ เราจะตอบกลับคุณโดยเร็วที่สุด
ส่ง

บ้าน

สินค้า

วอทส์แอพพ์

ติดต่อเรา